Product

ACF – 1MF Coriolis mass flow meter

Brief introduction ACF 1MFCoriolis mass flowmeter use the principle that fluidis in a rotating system while linear motion which will produce a direct mass flow meterwith corilios principle thatis proportional to the mass flow rate.Began in

Customized

  • Product description

Brief introduction
ACF – 1MF Coriolis mass flow meter use the principle that fluid is in a rotating system while linear motion, which will produce a direct mass flow meter with corilios principle that is proportional to the mass flow rate. Began in the early 1950s, but it was not until the mid-70s, this flow meter came to the market. To middle and later 80s, this flow meter was developed by instrument factories worldwide.  ACF – 1MF coriolis mass flow meter is independent research and development product manufactured by our company, product performance reaches the international advanced level, mass flow meter is high accuracy and can simultaneously measure the parameters such as flow, temperature and density. The measuring accuracy is not affected by medium pressure, temperature and viscosity, which had great significance in the trade measurement and quantitative control. The products are widely used in scientific research, petroleum, chemical, metallurgical, pharmaceutical, power plant, water supply and drainage, papermaking, food, energy, oil storage, mineral development, municipal, textile printing and dyeing and environmental protection and other fields.
 





 

 

Measure theory
Coriolis mass flow meter is a kind of new instrument to measure fluid mass flow rate directly and precisely, when the fluid flows in the rotating tube, it will produce a force to the wall, which is found by Coriolis when he studied the turbine, it was Coriolis force for short. Mass flow meter is based on coriolis force, there are two parallel vibrating-tubes inside the sensor, center is equipped with drive coil, both sides equipped with coil vibration pickings, excitation voltage offered by transmitter was added to the drive coil, the vibration tube do reciprocating cycle, when the fluid medium flows through the vibration tube during the industrial process, it will produce coriolis force effect on the vibration tube to make the two vibration tubes torsional vibration, the coils installed on both sides will generate two groups of different signals, the signal difference is proportional to the mass flow rate of fluid flowing through the sensor. Computer calculates the mass flow through the vibration control. For different density mediums flow through the sensor, the vibration frequency of the vibration pipe is different, which can calculate the medium density. The platinum resistance installed on the sensor vibration control can indirectly measure the temperature of the medium. 
Products patents:
Utility Model Patent Certificate:
①ZL2008 2 0028605.1  《digital instrument button and display device》
②ZL2009 2 0062360.9  《micro power consumption and low pressure drop sensor constant current drive circuit》
Patent for industrial design:
③ZL 2013 3 0412222.0  《instrument gauge (pressure gauge)》
Applications
- the oil industry, such as crude oil output measurement, moisture content, the single well production and transportation of crude oil metering;
- chemical industry;
- the food industry;
- pharmaceutical manufacturing industry, such as liquid pharmaceutical production measurement;
- the paper industry, such as pulp measurement;
- textile printing and dyeing industry;
- energy delivery metrics, such as liquefied petroleum gas metering;
- environmental protection industry, such as sewage treatment; Desulfurization process of slurry density measurement;
Features:
- measure the mass flow of the pipe directly, no effected by temperature, pressure, flow rate and so on;
- strong anti-jamming capability, high measurement precision, wide range ratio, operate stable and reliable, good repeatability;
- low installation requirement, low the fluid state requirement;
- in addition to the general's uniform fluid viscosity, but also can measure high viscosity, non-Newtonian flow;
- not only measurable for single-phase flow, but also can measure multiphase flow;
- the anti-corrosion performance is good, can measure all kinds of common corrosive fluid;
- shows the cumulative flow, instantaneous flow rate and temperature at the same time;
Technique Data:
Nominal Diameter: DN08~DN80
Dominal Pressure: (0~45)MPa
Medium Temperature: (-50~700)℃
System Accuracy: 0.2/0.5/1/1.5/2
Max Range to Min Range: 20:1
Operating Temperature: -30℃~70℃
Power Supply Mode: 12~30VDC
Output Signal: 4-20mA DC or RS485
Protection Degree: IP65
Exdl: ExdllCT6
Dimension: